You are here: home    Products    Storage    Fiber-to-SATA RAID Subsystems    2U Infortrend 4G FC to SA...

SKU# A12F-G2422-M2

2U Infortrend 4G FC to SATAII 12 bay RAID Subsystem

INFORTREND A12F-G2422M2 2U FC TO SATA-II SINGLE CONTROLLER RAID SUBSYSTEM 12 BAY COMBINING THE HIGH PERFORMANCE, RELIABILITY, AND EXTENSIVE CONNECTIVITY OF 4G FIBRE CHANNEL INTERFACES WITH THE COST-EFFECTIVE SATA DRIVE TECHNOLOGY, THESE ENTRY-LEVEL, SAN

Feel free to ask us for a quote on this product.

2U Infortrend  4G FC  to SATAII 12 bay RAID Subsystem
2U Infortrend  4G FC  to SATAII 12 bay RAID Subsystem
2U Infortrend  4G FC  to SATAII 12 bay RAID Subsystem

2U Infortrend 4G FC to SATAII 12 bay RAID Subsystem


Infortrend A12F-G2422M2 2U FC to SATA-II RAID subsystem 12 Bay

Combining the high performance, reliability, and extensive connectivity of 4G Fibre Channel interfaces with the cost-effective SATA drive technology, these entry-level, SAN-ready subsystems provide clustering capabilities for DAS, Fibre Channel SAN, and are well suited for imaging and archiving or secondary storage.

FC-4G to SATA-II single controller RAID subsystem
RAID5 configuration end-to-end I/O performance
Sequential read:545 MB/sec
Sequential write:345 MB/sec
Dual-speed fans to reduce noise
2U chassis providing up to 12TB of storage capacity
SATA NCQ support

Typical use
Disk-to-disk backup
Server-attached
Network data storage
Major industries such as medical imaging, security / CCTV, and digital media including video-on-demand stream editing and more.

RAID Multiple arrays configurable with dedicated or global hot spares
RAID levels supported RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
Online expansion by Adding new drives
Copying and replacing drives with drives of larger capacity
Automatic background rebuilds Configurable stripe size and write policy per arrayIntelligent drive handling In degraded mode -skips irreparable blocks to continue rebuild
In normal operation - data-block verification and repair
Host Interface Two (2) FC-4G through two (2) SFP host ports
Concurrent I/O commands
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Drive Interface Twelve (12) 3Gbps SATA-II, hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I or SATA-II disk drives
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
System Components Single controller configuration provides full RAID functionalities
One (1) EonStor enhanced 2U enclosure
One (1) RAID controller module
One (1) 256MB DDR RAM DIMM module (pre-installed on the controller module)
Two (2), hot-swappable, redundant, 350W power supply units
Two (A08F), hot-swappable, redundant, single-fan cooling modules running in high/low speeds
Twelve (12), hot-swappable drive trays
Two (2) front handles
Optional battery backup unit
Management Front LCD control panel for setup and configuration10/100 BaseT Ethernet for out-of-band managementOne (1) RS-232C serial port
for local access to firmware-embedded utility Firmware-embedded Java-based RAIDWatch® GUI manager
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
Cross-platform, remote administration with SSL
Out-of-band access via Ethernet
Centralized management to monitor and administer multiple RAID units on one screen
Configuration client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps,
MSN messenger,SMS short messages, and the configuration utility screen
SNMP agent support SNMP trap event notification with plain-text event message (no MIB file required)
SNMP V2.0 MIB file support with get-and-set commands
Indicators Onboard alarm is triggered when one of the following modules fails
RAID controller module
Cooling module
Power supply unit
Hard drive
BBU module
Module status LED indicators Two (2) per drive tray
One (1) per cooling module
One (1) per power supply unit
One (1) per BBU module
Three (3) per LCD panel
Five (5) per RAID controller module
Two (2) per Ethernet port
Module failure alert through I2C bus
Intelligent Drive Handling If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered.
Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors.
Media Scan handles low quality drives in both the degraded mode and during the rebuild process.
For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives,
power-failure management, and bad-drive handling during LD expansion.
Task Scheduler The Task Scheduler is combined with Media Scan so that the scanning operation can be scheduled beginning
at a specified start time and repeating at the configurable intervals. The operation is thus hands free. Each such
schedule can be defined to operate on individual hard drives, all drives of a certain class, all member drives of a
specified logical drive, or all member drives of all logical drives.
Interfaces Two (2) SFP ports for host connections
One (1) COM port (38400, n, 8, 1)
One (1) 10/100BaseT Ethernet port
Power Supply Two (2) redundant hot-swappable power supplies with PFC
Dimensions Chassis without handles 446(W) x 88(H) x 490(D) mm Chassis with handles 482 (W) x 88(H) x 505(D) mm Package 381H x567W x 772D mm
System Weight Net weight 23.5kg Gross weight 25kg

Melrow SKU# A12F-G2422-M2

INFORTREND A12F-G2422M2 2U FC TO SATA-II SINGLE CONTROLLER RAID SUBSYSTEM 12 BAY COMBINING THE HIGH PERFORMANCE, RELIABILITY, AND EXTENSIVE CONNECTIVITY OF 4G FIBRE CHANNEL INTERFACES WITH THE COST-EFFECTIVE SATA DRIVE TECHNOLOGY, THESE ENTRY-LEVEL, SAN

 Loading...